Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 333-337, 2018.
Article in English | WPRIM | ID: wpr-717308

ABSTRACT

BACKGROUND: Pinch-off syndrome (POS) is a rare complication after totally implantable venous access device (TIVAD) implantation. In cancer patients, it is important to prevent this rare complication and to recognize it early if it does occur. We present a case series of POS after TIVAD implantation and the results of a literature search about this complication. METHODS: From July 2006 to December 2015, 924 permanent implantable central venous catheter implantation procedures were performed. The most common indication was vascular access for chemotherapy. RESULTS: POS occurred in 5 patients in our clinic. Two patients experienced POS within 2 weeks, and the other 3 patients were admitted to department of surgery, Istanbul Faculty of Medicine at 6 to 14 months following implantation. The catheters were found to be occluded during medication administration, and all patients complained of serious pain. The transected fragments of the catheters had migrated to the heart. They were successfully removed under angiography with a single-loop snare. CONCLUSION: POS is a serious complication after TIVAD implantation. It is important to be aware of this possibility and to make an early diagnosis in order to prevent complications such as drug extravasation and occlusion events.


Subject(s)
Humans , Angiography , Catheters , Central Venous Catheters , Drug Therapy , Early Diagnosis , Heart , SNARE Proteins
2.
Korean Journal of Radiology ; : 314-323, 2012.
Article in English | WPRIM | ID: wpr-89583

ABSTRACT

OBJECTIVE: To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. MATERIALS AND METHODS: We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. RESULTS: A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). CONCLUSION: Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Catheterization, Central Venous/methods , Fluoroscopy , Jugular Veins , Postoperative Complications/epidemiology , Radiography, Interventional , Republic of Korea/epidemiology , Retrospective Studies , Treatment Outcome , Ultrasonography, Interventional